Serial layers of depth media and membrane provide long lasting protection of final filters

Extended life and high retention efficiency make Clearflow™ an ideal filter for the clarification of particulate-laden solutions as commonly found in food and beverage production.

At the heart of the Clearflow™ design is a serial layer matrix of depth media and polyethersulfone (PES) membrane. This combination offers superior flow and long-lasting protection for downstream final filters. Clearflow™ cartridges are also non-fiber-releasing and will not unload contaminants, even under pulsing conditions.

Clearflow™ cartridges are available in 0.2, 0.5, or 0.8 µm nominal ratings, and with your choice of glass fiber or polypropylene prefiltration media. They are manufactured in a certified clean room environment. The Biological Grade version provides qualitative microbial retention. General Grade cartridges are for prefiltration applications, and are bulk packaged and economically priced.
Unit of Measure

Specifications

Prefilter Layer

N/A Polypropylene

Insert Style

N/A No Insert (Standard)

End Fittings

N/A 213/Recessed Endcap (Ametek®)

Note

N/A Not available in Biological Grade

Nominal Length

N/A 10 in250 mm

Filter Rating

N/A 0.2 µm

Gasket/O-Ring Material

N/A Buna N EPDM FEP-Encapsulated Silicone (O-Rings only) FEP-Encapsulated Viton® (O-Rings only) None Silicone Viton®

Thickness (Gaskets only)

N/A 0.125" (3 mm) 0.200" (5 mm) (1) 0.200" (5 mm) & (1) 0.125" (3 mm) No Gasket

Grade

N/A Biological General

Maximum Forward Operating Conditions @ 75ºF (24ºC)

N/A 60 psid4.1 bar

Maximum Reverse Operating Conditions @ 75ºF (24ºC)

N/A 30 psid2.0 bar
Typical Water Flow Rates1 N/A 2.0 gpm/psid10.98 lpm/100 mbar

Integrity Test Values

Bubble Point

N/A 30 psig21. bar

Diffusional Flow

N/A 20 mL/min

Diffusional Test Pressure

N/A 24 psig1.7 bar

Note

N/A Tested in deionized water

Benefits

N/A

  • Excellent particle retention provides for excellent protection of downstream filters
  • High flow rate reduces processing time
  • Long service life minimizes changeout frequency
  • Integrity testable
  • Steam Sterilizable

  • Applications

    N/A Prefiltration/clarification of:

  • Syrups
  • Wine/beer/bottled water
  • Sweetners
  • Viscous liquids

  • Materials of Construction

    N/A Either glass fiber or polypropylene depth media over with a PES membrane layer. Media support layers and cartridge structure are polypropylene.

    All components meet USP-XXIV Class VI-121ºC criteria and are thermally bonded to assure integrity and purity.

    Steam Sterlizable and Sanitizable

    N/A Cartridges can be steamed or autoclaved for at least 10 one-hour cycles @ 121ºC (250ºF). Cartridges can also be hot water or chemically sanitized in place using common sanitizing agents. Please contact Parker for detailed procedures.

    Integrity Tested

    N/A All biological grade elements are integrity tested by a diffusive flow method during manufacturing

    Technical Support and Product Information

    N/A Parker provides our customers with unsurpassed product consistency and cost efficiency. Our experienced professionals can help you select the right solution for your application. Orders can be emailed directly to PAFsales@parker.com. For additional information contact your local distributor. Information on product specifications, applications and chemical compatibility can be found on our web site at www.parker.com or through the Oxnard office.

    Parker designs and manufactures an extensive line of innovative solutions for specific applications in the Microelectronics, Biopharmaceutical, Food and Beverage, Coatings and Inks, Process and Chemical industries.

    Note

    N/A Specifications are subject to change without notification.
    Clearflow™ is a trademark of Parker Hannifin Corporation.
    Viton® is a registered trademark of E.I. DuPont de Nemours & Co., Inc.
    Ametek® is a registered trademark of Ametek Calibration Instruments

    • 1 For fluids with viscosity of 1cP, per 10 inch (250 mm) cartridge equivalent