Items |
MNY911AA Memtrex™ NY Pleated Filters with Hydrophilic Nylon 66 Membrane |
MNY911AB Memtrex™ NY Pleated Filters with Hydrophilic Nylon 66 Membrane |
MNY911AC Memtrex™ NY Pleated Filters with Hydrophilic Nylon 66 Membrane |
MNY911AG Memtrex™ NY Pleated Filters with Hydrophilic Nylon 66 Membrane |
MNY911AH Memtrex™ NY Pleated Filters with Hydrophilic Nylon 66 Membrane |
|||||
Type | N/A MNY | |||||||||
Micron Rating | N/A 0.1 µm | |||||||||
Nominal Cartridge Length | N/A 10 in25.4 cm | |||||||||
End #1 Adapter | N/A Open End Gasket | |||||||||
End #2 Adapter | N/A Open End Gasket | N/A 120 O-Ring | N/A 213 O-Ring | N/A Closed End Cap | N/A Fin Adapter | |||||
Elastomer Material1 | N/A Buna-N EPDM Silicone Viton | |||||||||
Media Material | N/A 2 Layers of Nylon 66 Membrane (prefilter layer over final layer) | |||||||||
Support Layers | N/A Polyester Microfiber | |||||||||
Core and Cage | N/A Polypropylene | |||||||||
Endcaps and Adapters | N/A Polyester | |||||||||
Nominal Outside Diameter | N/A 2.75 in70 mm | |||||||||
Nominal Inside Diameter | N/A 1.25 in31 mm | |||||||||
Effective Filtration Area | N/A 7 ft²1 m² | |||||||||
Maximum Forward Differential Pressure @ 70ºF (21ºC) | N/A 60 psi4.1 bar | |||||||||
Maximum Reverse Differential Pressure @ 70ºF (21ºC) | N/A 30 psi2.1 bar | |||||||||
Maximum Operating Temperature at 10 psid (0.7 bar) in Water | N/A 180 ºF82 ºC | |||||||||
Integrity Testing2 | N/A ≤ 50 cc/min at 40 psig≤ 50 cc/min at 2.76 bar | |||||||||
Note | N/A Trademark of General Electric Company; may be registered in one or more countries. | |||||||||
Typical Applications |
N/A
MNY filters have excellent chemical compatibility making them the ideal choice for a broad range of applications such as high purity water, strong solvents, photoresists and other critical process fluid systems. Typical applications include:
|
|||||||||
General Properties | N/A Memtrex NY filters are available the following absolute pore size micron ratings: 0.1, 0.2, 0.45, 0.65 and 1.0 µm. Tables 1, 2, 3, 4 and 5 show further details on materials of construction, dimensions, operational limits, integrity testing and flow performance. | |||||||||
Additional Information |
N/A
|
|||||||||
|