Items |
SG-10010-002 Clearflow™ Filters |
SG-10010-005 Clearflow™ Filters |
SG-10010-008 Clearflow™ Filters |
SG-10020-002 Clearflow™ Filters |
SG-10020-005 Clearflow™ Filters |
|||||
Prefilter Layer | N/A Glass Fiber | |||||||||
Insert Style | N/A No Insert (Standard) | |||||||||
End Fittings | N/A DOE (CUNO®) | |||||||||
Note | N/A Not available in Biological Grade | |||||||||
Nominal Length | N/A 10 in250 mm | N/A 10 in250 mm | N/A 10 in250 mm | N/A 20 in500 mm | N/A 20 in500 mm | |||||
Filter Rating | N/A 0.2 µm | N/A 0.5 µm | N/A 0.8 µm | N/A 0.2 µm | N/A 0.5 µm | |||||
Gasket/O-Ring Material | N/A Buna N EPDM FEP-Encapsulated Silicone (O-Rings only) FEP-Encapsulated Viton® (O-Rings only) None Silicone Viton® | |||||||||
Thickness (Gaskets only) | N/A 0.125" (3 mm) 0.200" (5 mm) (1) 0.200" (5 mm) & (1) 0.125" (3 mm) No Gasket | |||||||||
Grade | N/A Biological General | |||||||||
Maximum Forward Operating Conditions @ 75ºF (24ºC) | N/A 60 psid4.1 bar | |||||||||
Maximum Reverse Operating Conditions @ 75ºF (24ºC) | N/A 30 psid2.0 bar | |||||||||
Bubble Point | N/A 30 psig21. bar | N/A 17 psig1.2 bar | N/A 14 psig1.0 bar | N/A 30 psig21. bar | N/A 17 psig1.2 bar | |||||
Diffusional Flow | N/A 20 mL/min | |||||||||
Diffusional Test Pressure | N/A 24 psig1.7 bar | N/A 13 psig0.9 bar | N/A 11 psig0.7 bar | N/A 24 psig1.7 bar | N/A 13 psig0.9 bar | |||||
Note | N/A Tested in deionized water | |||||||||
Typical Water Flow Rates1 | N/A 4.0 gpm/psid21.96 lpm/100 mbar | N/A 7.5 gpm/psid41.18 lpm/100 mbar | N/A 8.5 gpm/psid46.67 lpm/100 mbar | N/A 4.0 gpm/psid21.96 lpm/100 mbar | N/A 7.5 gpm/psid41.18 lpm/100 mbar | |||||
Benefits |
N/A
|
|||||||||
Applications |
N/A
Prefiltration/clarification of: |
|||||||||
Materials of Construction |
N/A
Either glass fiber or polypropylene depth media over with a PES membrane layer. Media support layers and cartridge structure are
polypropylene. All components meet USP-XXIV Class VI-121ºC criteria and are thermally bonded to assure integrity and purity. |
|||||||||
Steam Sterlizable and Sanitizable | N/A Cartridges can be steamed or autoclaved for at least 10 one-hour cycles @ 121ºC (250ºF). Cartridges can also be hot water or chemically sanitized in place using common sanitizing agents. Please contact Parker for detailed procedures. | |||||||||
Integrity Tested | N/A All biological grade elements are integrity tested by a diffusive flow method during manufacturing | |||||||||
Technical Support and Product Information |
N/A
Parker provides our customers with unsurpassed product consistency and cost efficiency. Our experienced professionals can help you select the right solution for your application. Orders can be emailed directly to PAFsales@parker.com. For additional information contact your local distributor. Information on product specifications, applications and chemical compatibility can be found on our web site at www.parker.com or through the Oxnard office. Parker designs and manufactures an extensive line of innovative solutions for specific applications in the Microelectronics, Biopharmaceutical, Food and Beverage, Coatings and Inks, Process and Chemical industries. |
|||||||||
Note |
N/A
Specifications are subject to change without notification. Clearflow™ is a trademark of Parker Hannifin Corporation. Viton® is a registered trademark of E.I. DuPont de Nemours & Co., Inc. Ametek® is a registered trademark of Ametek Calibration Instruments |
|||||||||
|