argreen Process Technologies | From Coarse Straining Down to Microfiltration, Reverse Osmosis and Ultra Filtration
Pargreen Process Technologies
1224 Capitol Drive
Addison, IL. 60101
USA

Call: 800.323.2810
Fax: 630.628.3050
Email: sales@pargreen.com
Website: www.pargreen.com
Print Back
The AD HR series, family of proprietary thin film reverse osmosis membrane elements, is characterized by an excellent sodium chloride rejection. AD HR series is selected when high quality permeate is demanded from seawater that is relatively high in TDS.

AD HR series new membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceeding 800psi (5,516kPa) and elevated temperatures).
Element-Dimensions-Diagram---Male
Unit of Measure
Items Element-Dimensions-Diagram---Male
AD4040FM HR
AD HR Series Seawater RO High Rejection Elements
Element-Dimensions-Diagram---Male
AD8040F HR
AD HR Series Seawater RO High Rejection Elements
Element-Dimensions-Diagram---Male
AD8040F-400 HR
AD HR Series Seawater RO High Rejection Elements
Membrane N/A Thin-Film Membrane (TFM™)
Average Permeate Flow N/A 1400 gpd5.3 m³/day N/A 6000 gpd22.7 m³/day N/A 6500 gpd24.6 m³/day
Average NaCl Rejection N/A 99.7 %
Minimum NaCl Rejection N/A 99.3 %
Note N/A Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%.
Testing conditions: 32,000mg/l NaCl solution at 800psi (5,516kPa) operating pressure, 77ºF, pH7.5 and 7% recovery.
Active Area N/A 86 ft²8.0 m² N/A 370 ft²34.4 m² N/A 400 ft²37.2 m²
Outer Wrap N/A Fiberglass
Part Number N/A 3034297 N/A 3037409 N/A 3037470
Dimension A (Length) N/A 40.0 in101.6 cm
Dimension B1 N/A 0.75 inOD: 1.90 cm N/A 1.125 in2.86 cm N/A 1.125 in2.86 cm
Dimension C (Outside Diameter) N/A 3.9 in9.9 cm N/A 7.9 in20.1 cm N/A 7.9 in20.1 cm
Boxed Weight N/A 9 lb4 kg N/A 35 lb16 kg N/A 35 lb16 kg
Typical Operating Pressure N/A 800 psi5516 kPa
Typical Operating Flux N/A 7 - 11 GFD12 - 19 LMH
Maximum Operating Pressure N/A 1200 psi8274 kPa
Maximum Continuous Operation Temperature N/A 122 ºF50 ºC
Maximum Clean-In-Place (CIP) Temperature N/A 122 ºF50 ºC
Optimum Rejection pH Range N/A 7.0 - 7.5
Continuous Operation pH Range N/A 4.0 - 11.0
Clean-In-Place (CIP) pH Range N/A 2.0 - 11.5
Maximum Pressure Drop Over an Element N/A 12 psi83 kPa
Maximum Pressure Drop Per Housing N/A 50 psi345 kPa
Chlorine Tolerance N/A 1,000+ ppm-hours, Dechlorination Recommended
Feedwater N/A NTU < 1 SDI < 5
Note N/A These elements are bagged wet before shipping.
Trademark of General Electric Company; may be registered in one or more countries.
  • 1 Internal diameter unless specified OD (outside diameter).