argreen Process Technologies | From Coarse Straining Down to Microfiltration, Reverse Osmosis and Ultra Filtration
Pargreen Process Technologies
1224 Capitol Drive
Addison, IL. 60101
USA

Call: 800.323.2810
Fax: 630.628.3050
Email: sales@pargreen.com
Website: www.pargreen.com
Print Back
The A-Series family of proprietary thin-film reverse osmosis membrane is characterized by high flux and high sodium chloride rejection. AG HR Brackish Water Elements are selected when high rejection and operating pressures as low as 200 psi (1,379 kPa) are desired. These elements are recommended for brackish water with salt concentration (TDS) levels between 1,000 and 10,000mg/l or when very high salt rejection of monovalent ions is required.

AG HR high rejection brackish water elements feature a Fiberglass outer wrap and female end connections.
Element-Dimensions-Diagram---Male
Unit of Measure
Items Element-Dimensions-Diagram---Male
AG8040F,WET HR
AG HR Series High Rejection Brackish Water RO Elements
Element-Dimensions-Diagram---Male
AG8040F-400,WET HR
AG HR Series High Rejection Brackish Water RO Elements
Membrane N/A Thin-Film Membrane (TFM™)
Average Permeate Flow N/A 9500 gpd36.0 m³/day N/A 10200 gpd38.6 m³/day
Average NaCl Rejection N/A 99.7 %
Minimum NaCl Rejection N/A 99.2 %
Note N/A Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%.
Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating pressure, 77ºF, pH7 and 15% recovery.
Active Area N/A 365 ft²33.9 m² N/A 400 ft²37.2 m²
Outer Wrap N/A Fiberglass
Part Number N/A 3040993 N/A 3040994
Dimension A (Length) N/A
Dimension B1 N/A
Dimension C (Outside Diameter) N/A
Boxed Weight N/A
Typical Operating Pressure N/A 200 psi1380 kPa
Typical Operating Flux N/A 10 - 20 GFD15 - 35 LMH
Maximum Operating Pressure N/A 600 psi4137 kPa
Maximum Continuous Operation Temperature N/A 122 ºF50 ºC
Maximum Clean-In-Place (CIP) Temperature N/A 122 ºF50 ºC
Optimum Rejection pH Range N/A 7.0 - 7.5
Continuous Operation pH Range N/A 4.0 - 11.0
Clean-In-Place (CIP) pH Range N/A 2.0 - 11.5
Maximum Pressure Drop Over an Element N/A 12 psi83 kPa
Maximum Pressure Drop Per Housing N/A 50 psi345 kPa
Chlorine Tolerance N/A 1,000+ ppm-hours, Dechlorination Recommended
Feedwater N/A NTU < 1 SDI < 5
Note N/A Trademark of General Electric Company; may be registered in one or more countries.
  • 1 Internal diameter.