Membrane |
N/A A-Series, Thin-Film Membrane (TFM™) |
Flow Average |
N/A 9200 gpd34.8 m³/day |
Salt Rejection Average (NaCl) |
N/A 99.5 % |
Salt Rejection Minimum (NaCl) |
N/A 99.0 % |
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 2,000 ppm NaCl solution at 225 psig (1,551 kPa) operating pressure, 77 ºF, pH 7.5 and 15% recovery. |
Active Area |
N/A 350 ft²32.5 m² |
Outer Wrap |
N/A Fiberglass |
Part Number |
N/A 1206779 |
Dimension C (Outside Diameter) |
N/A 7.9 in20.1 cm |
Dimension A (Length) |
N/A 40.0 in101.6 cm |
Dimension B1 | N/A 1.125 in2.86 cm |
Boxed Weight |
N/A 32 lb14.5 kg |
Typical Operating Pressure |
N/A 200 psig1379 kPa |
Typical Operating Flux |
N/A 10 - 20 GFD15 - 35 LMH |
Maximum Pressure (Tape Elements) |
N/A 450 psig3103 kPa |
Maximum Pressure (Other Outerwrap) |
N/A 600 psig4137 kPa |
Maximum Operating Temperature |
N/A 122 ºF50 ºC |
Maximum Cleaning Temperature |
N/A 122 ºF50 ºC |
Optimum Rejection Recommended pH |
N/A 7.0 - 7.5 |
Operating Range Recommended pH |
N/A 4.0 - 11.0 |
Cleaning Range Recommended pH |
N/A 2.0 - 11.5 |
Recommended Pressure Drop Over an Element |
N/A 12 psig83 kPa |
Recommended Pressure Drop Per Housing |
N/A 50 psig345 kPa |
Chlorine Tolerance |
N/A 1,000+ ppm-hours, Dechlorination Recommended |
Feedwater |
N/A NTU < 1 SDI < 5 |