					 CE2540FM CE Series Brackish Water RO Elements (Cellulose Acetate)  | 
				
					 CE4025T CE Series Brackish Water RO Elements (Cellulose Acetate)  | 
				
					 CE4026F CE Series Brackish Water RO Elements (Cellulose Acetate)  | 
				
					 CE4040F CE Series Brackish Water RO Elements (Cellulose Acetate)  | 
				
					 CE4040FM CE Series Brackish Water RO Elements (Cellulose Acetate)  | 
                |||||
| Membrane | N/A C-series, Cellulose Acetate | |||||||||
| Flow Average | N/A 630 gpd2.4 m³/day | N/A 1300 gpd4.9 m³/day | N/A 1300 gpd4.9 m³/day | N/A 2100 gpd7.9 m³/day | N/A 2000 gpd7.6 m³/day | |||||
| Salt Rejection Average (NaCl) | N/A 97.5 % | |||||||||
| Salt Rejection Minimum (NaCl) | N/A 95.0 % | |||||||||
| Note | 
                                            
                                            
                                                N/A
                                                Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 2,000 ppm NaCl solution at 425 psig (2,930 kPa) operating pressure, 77ºF, pH 6.5 and 15% recovery.  | 
                                |||||||||
| Active Area | N/A 27 ft²2.5 m² | N/A 59 ft²5.5 m² | N/A 59 ft²5.5 m² | N/A 95 ft²8.8 m² | N/A 85 ft²7.9 m² | |||||
| Outer Wrap | N/A Fiberglass | N/A Tape | N/A Fiberglass | N/A Fiberglass | N/A Fiberglass | |||||
| Part Number | N/A 1206854 | N/A 1206870 | N/A 1206875 | N/A 1206878 | N/A 1231443 | |||||
| Dimension A (Length) | N/A 40.0 in101.6 cm | N/A 25.0 in63.5 cm | N/A 26.0 in66.7 cm | N/A 40.0 in101.6 cm | N/A 40.0 in101.6 cm | |||||
| Dimension B1 | N/A 0.75 inOD: 1.90 cm | N/A 0.625 in1.59 cm | N/A 0.625 in1.59 cm | N/A 0.625 in1.59 cm | N/A 0.75 inOD: 1.90 cm | |||||
| Dimension C (Outside Diameter) | N/A 2.4 in6.1 cm | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | |||||
| Boxed Weight | N/A 5 lb2.3 kg | N/A 5 lb2.3 kg | N/A 6 lb2.7 kg | N/A 8 lb3.5 kg | N/A 8 lb3.5 kg | |||||
| Typical Operating Pressure | N/A 140 - 400 psig965 - 2758 kPa | |||||||||
| Typical Operating Flux | N/A 10 - 18 GFD17 - 30 LMH | |||||||||
| Maximum Pressure | N/A 450 psig3103 kPa | |||||||||
| Maximum Operating Temperature | N/A 86 ºF30 ºC | |||||||||
| Maximum Cleaning Temperature | N/A 86 ºF30 ºC | |||||||||
| Operating Range Recommended pH | N/A 5.0 - 6.5 | |||||||||
| Cleaning Range Recommended pH | N/A 3.0 - 8.0 | |||||||||
| Recommended Pressure Drop Over an Element | N/A 12 psig83 kPa | |||||||||
| Recommended Pressure Drop Per Housing | N/A 50 psig345 kPa | |||||||||
| Chlorine Tolerance | 
                                            
                                            
                                                N/A
                                                1 ppm Maximum Continuous 30 ppm for 30 min. During Sanitization  | 
                                |||||||||
| Feedwater | N/A NTU < 1 SDI < 5 | |||||||||
| Note | 
                                            
                                            
                                                N/A
                                                These elements are shipped dry. Trademark of General Electric Company; may be registered in one or more countries.  | 
                                |||||||||
                        
  | 
                ||||||||||