                                                                                Membrane | 
                                                                        N/A Thin-Film Membrane (TFM™) | 
                                                                                Average Permeate Flow | 
                                                                        N/A 10200 gpd38.6 m³/day | 
                                                                                Average NaCl Rejection | 
                                                                        N/A 99.7 % | 
                                                                                Minimum NaCl Rejection | 
                                                                        N/A 99.2 % | 
                                                                                Note | 
                                                                        
                                                                                    
                                                                                        N/A
                                                                                          Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 2,000ppm NaCl solution at 225psi (1,550kPa) operating pressure, 77ºF, pH7 and 15% recovery.  | 
                                                    
                                                                                Active Area | 
                                                                        N/A 400 ft²37.2 m² | 
                                                                                Outer Wrap | 
                                                                        N/A Fiberglass | 
                                                                                Part Number | 
                                                                        N/A 3040994 | 
                                                                                Typical Operating Pressure | 
                                                                        N/A 200 psi1380 kPa | 
                                                                                Typical Operating Flux | 
                                                                        N/A 10 - 20 GFD15 - 35 LMH | 
                                                                                Maximum Operating Pressure | 
                                                                        N/A 600 psi4137 kPa | 
                                                                                Maximum Continuous Operation Temperature | 
                                                                        N/A 122 ºF50 ºC | 
                                                                                Maximum Clean-In-Place (CIP) Temperature | 
                                                                        N/A 122 ºF50 ºC | 
                                                                                Optimum Rejection pH Range | 
                                                                        N/A 7.0 - 7.5 | 
                                                                                Continuous Operation pH Range | 
                                                                        N/A 4.0 - 11.0 | 
                                                                                Clean-In-Place (CIP) pH Range | 
                                                                        N/A 2.0 - 11.5 | 
                                                                                Maximum Pressure Drop Over an Element | 
                                                                        N/A 12 psi83 kPa | 
                                                                                Maximum Pressure Drop Per Housing | 
                                                                        N/A 50 psi345 kPa | 
                                                                                Chlorine Tolerance | 
                                                                        N/A 1,000+ ppm-hours, Dechlorination Recommended | 
                                                                                Feedwater | 
                                                                        N/A NTU < 1 SDI < 5 |