Strainer Model |
N/A F-Series 2200 External Backwashing Multiplex Unit |
Body Inlet / Outlet Size |
N/A 3 in76.2 mm |
Inlet / Outlet Header Size1 | N/A 3 in4 in8 in10 in12 in76.2 mm101.8 mm203.2 mm254 mm304.8 mm |
Body Diameter |
N/A 4.5 in114.3 mm |
Screen Length |
N/A 36 in914.4 mm |
Element Styles Available2 | N/A 3.25 in (82.3mm) Diameter Single, Tri-cluster, Accuflux - 7 |
Pressure Rating3 | N/A 250 psi17.2 bar |
Air Requirement (Automated Units) @ 5 cfm, for Sequencing |
N/A 60 - 120 psi4.1 - 8.3 bar |
Electrical Requirement (Automated Units) |
N/A 110/220 V, 50/60 Hz, Single Phase |
Filter Media Material |
N/A Fabric: 230 - 1 micron Slotted: 1,600 - 25 microns Wire mesh: 1,650 - 2 microns |
N/A
TRI-CLUSTER® - three-tube 1 1/2" diameter media for 40 percent greater surface area than single element designs, with an economical initial investment |
N/A
While the filtration media provides some of the filtration action, collected contaminants actually further increase efficiency. We call this phenomenon "cake formation." The collected solids (or "cake") trap additional contaminants. The key to making this principle work is timely cleaning - too soon and you lose the benefit, too late and the system flow becomes hindered. |
N/A
Ronningen-Petter F-Series is available in both internal and external backwashing configurations. Internal backwashing systems are designed for processes with system pressure greater than or equal to 45 psi (3.1 bar) and low viscosity process liquids. External backwashing systems are designed for applications with high-value process liquids and/or processes with low operating pressures. |