Pore size |
N/A 0.45 µm |
316 SS Ring |
N/A Ring |
Cartridge Length |
N/A 30 in76.2 cm |
End Caps |
N/A 020 O-ring / Plug 213/119 Internal O-ring / Plug 213/119 Internal O-ring DOE 2-222 O-ring / Flat 2-222 O-ring / Plug 2-222 O-ring / Spear 2-222 O-ring 3 Tab / Flat 2-222 O-ring 3 Tab / Spear 2-223 O-ring / Flat 2-223 O-ring / Spear 2-226 O-ring / Flat 2-226 O-ring / Spear Flat Gasket / Plug Flat Gasket, DOE |
Flow Rate |
N/A 5.0 gpm13.92 lpm |
Filtration Media |
N/A Polypropylene |
Filtration Media Support Material |
N/A Polypropylene |
End Caps Material |
N/A Polypropylene |
Center Core Material |
N/A Polypropylene |
Outer Support Cage Material |
N/A Polypropylene |
Sealing Method |
N/A Thermal Bonding |
O-Rings Material |
N/A Buna EP PTFE® Encapsulated Silicone PTFE® Encapsulated Viton® Silicone Viton® |
Note |
N/A All materials of construction are FDA accepted. Final assemblies have been validated to pass USP class 6 Toxicology extractable tests, oxidizable substances for plastics, endotoxin level and other quality tests. |
Forward Differential Pressure at 20ºC |
N/A 50 psi3.4 bar |
Reverse Differential Pressure at 20ºC |
N/A 40 psi2.7 bar |
Operating Temperature at 10 psid (0.69 bar) in Water |
N/A 180 ºF82 ºC |
Recommended Change Out Pressure |
N/A 35 psid2.4 bar |
Nominal Length |
N/A 5 to 40 in12.7 to 101.6 cm |
Nominal Outside Diameter |
N/A 2.75 in7.0 cm |
Filtration Area Per 10" Length |
N/A Upto to 7.2 ft²0.67 m² |
Filtered Hot Water |
N/A 194 ºF90 ºC |
Autoclave |
N/A 250ºF (121ºC), 30 min, multiple cycles |
In-Line Steam |
N/A 275ºF (135ºC), 30 min, multiple cycles |
Chemical Sanitization |
N/A Industry standard concentrations of hydrogen peroxide, paracetic acid, sodium hypochlorite and other selected chemicals. Sanitization protocols designed to extend the useful life of GPD cartridges are available from Critical Process Filtration, Inc. |
N/A
Filtration of: |
N/A See the Flow Rate table in more image which represents typical water flow at a one psi (69 mbar) pressure differential across a single 10-inch cartridge element. The test fluid is water at ambient temperature. Extrapolation for housings with multiple elements and higher pressure drops is acceptable, but as flows increase the pressure drop of the housing becomes more apparent. |
N/A Cartridges are factory tested for integrity before shipment. Field Duplication of these tests is not practical because of the complexity of the testing process and absence of commercial portable testing equipment. |
N/A Our goal is to ensure our customers the greatest possible value for their filtration dollar. We achieve both low cost manufacture and high quality by employing state of the art manufacturing equipment. This computer-controlled equipment is highly automated, reducing hand operations that compromise quality. Each operation, including assembly, testing, cleaning, drying and packaging, is done in appropriately rated clean rooms. Critical Process Filtration manages an ISO 9000 facility that produces validated products to rigorous standards. Manufacturing is controlled using sophisticated MRP software that is networked to work stations in manufacturing centers and inspection points. During the manufacturing and inspection processes, data is collected "real time" from machinery and measuring instruments. This allows variable and attribute data to be quickly and easily analyzed to facilitate constant improvements in both quality and cost. |
N/A Critical Process Filtration, Inc. is a vertically integrated supplier of filtration products and services to industries in which filtration is considered to be a critical part of the manufacturing process. We manufacture a complete line of products to help you achieve all your filtration requirements from a single source. |