argreen Process Technologies | From Coarse Straining Down to Microfiltration, Reverse Osmosis and Ultra Filtration
Pargreen Process Technologies
1224 Capitol Drive
Addison, IL. 60101
USA

Call: 800.323.2810
Fax: 630.628.3050
Email: sales@pargreen.com
Website: www.pargreen.com
Print Back
The AD HR series, family of proprietary thin film reverse osmosis membrane elements, is characterized by an excellent sodium chloride rejection. AD HR series is selected when high quality permeate is demanded from seawater that is relatively high in TDS.

AD HR series new membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceeding 800psi (5,516kPa) and elevated temperatures).
Unit of Measure

Element Specification

Membrane

N/A Thin-Film Membrane (TFM™)

Average Permeate Flow

N/A 6500 gpd24.6 m³/day

Average NaCl Rejection

N/A 99.7 %

Minimum NaCl Rejection

N/A 99.3 %

Note

N/A Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%.
Testing conditions: 32,000mg/l NaCl solution at 800psi (5,516kPa) operating pressure, 77ºF, pH7.5 and 7% recovery.

Active Area

N/A 400 ft²37.2 m²

Outer Wrap

N/A Fiberglass

Part Number

N/A 3037470

Dimensions and Weight

Dimension A (Length)

N/A 40.0 in101.6 cm
Dimension B1 N/A 1.125 in2.86 cm

Dimension C (Outside Diameter)

N/A 7.9 in20.1 cm

Boxed Weight

N/A 35 lb16 kg

Operating and CIP parameters

Typical Operating Pressure

N/A 800 psi5516 kPa

Typical Operating Flux

N/A 7 - 11 GFD12 - 19 LMH

Maximum Operating Pressure

N/A 1200 psi8274 kPa

Maximum Continuous Operation Temperature

N/A 122 ºF50 ºC

Maximum Clean-In-Place (CIP) Temperature

N/A 122 ºF50 ºC

Optimum Rejection pH Range

N/A 7.0 - 7.5

Continuous Operation pH Range

N/A 4.0 - 11.0

Clean-In-Place (CIP) pH Range

N/A 2.0 - 11.5

Maximum Pressure Drop Over an Element

N/A 12 psi83 kPa

Maximum Pressure Drop Per Housing

N/A 50 psi345 kPa

Chlorine Tolerance

N/A 1,000+ ppm-hours, Dechlorination Recommended

Feedwater

N/A NTU < 1 SDI < 5

Note

N/A These elements are bagged wet before shipping.
Trademark of General Electric Company; may be registered in one or more countries.

  • 1 Internal diameter unless specified OD (outside diameter).