CE Series Brackish Water RO Elements (Cellulose Acetate)
RO-NF-UF Membranes
The C-Series family, a triacetate/diacetate blend, has a higher flux and better mechanical stability than standard cellulose acetate. CA-Series elements offer a lower per element cost and increased chlorine resistance compared to thin-film elements.
CE Brackish Water Elements are used for brackish water desalination and process stream concentration at 425 psig operating pressure (2,930 kPa).
CE Brackish Water Elements are used for brackish water desalination and process stream concentration at 425 psig operating pressure (2,930 kPa).
Unit of Measure
Items |
/Asset/Element-Dimensions-Diagram---Male.JPG CE2540FM CE Series Brackish Water RO Elements (Cellulose Acetate) |
/Asset/Element-Dimensions-Diagram---Male.JPG CE4025T CE Series Brackish Water RO Elements (Cellulose Acetate) |
/Asset/Element-Dimensions-Diagram---Male.JPG CE4026F CE Series Brackish Water RO Elements (Cellulose Acetate) |
/Asset/Element-Dimensions-Diagram---Male.JPG CE4040F CE Series Brackish Water RO Elements (Cellulose Acetate) |
/Asset/Element-Dimensions-Diagram---Male.JPG CE4040FM CE Series Brackish Water RO Elements (Cellulose Acetate) |
|||||
Membrane | N/A C-series, Cellulose Acetate | |||||||||
Flow Average | N/A 630 gpd2.4 m³/day | N/A 1300 gpd4.9 m³/day | N/A 1300 gpd4.9 m³/day | N/A 2100 gpd7.9 m³/day | N/A 2000 gpd7.6 m³/day | |||||
Salt Rejection Average (NaCl) | N/A 97.5 % | |||||||||
Salt Rejection Minimum (NaCl) | N/A 95.0 % | |||||||||
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 2,000 ppm NaCl solution at 425 psig (2,930 kPa) operating pressure, 77ºF, pH 6.5 and 15% recovery. |
|||||||||
Active Area | N/A 27 ft²2.5 m² | N/A 59 ft²5.5 m² | N/A 59 ft²5.5 m² | N/A 95 ft²8.8 m² | N/A 85 ft²7.9 m² | |||||
Outer Wrap | N/A Fiberglass | N/A Tape | N/A Fiberglass | N/A Fiberglass | N/A Fiberglass | |||||
Part Number | N/A 1206854 | N/A 1206870 | N/A 1206875 | N/A 1206878 | N/A 1231443 | |||||
Dimension A (Length) | N/A 40.0 in101.6 cm | N/A 25.0 in63.5 cm | N/A 26.0 in66.7 cm | N/A 40.0 in101.6 cm | N/A 40.0 in101.6 cm | |||||
Dimension B1 | N/A 0.75 inOD: 1.90 cm | N/A 0.625 in1.59 cm | N/A 0.625 in1.59 cm | N/A 0.625 in1.59 cm | N/A 0.75 inOD: 1.90 cm | |||||
Dimension C (Outside Diameter) | N/A 2.4 in6.1 cm | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | |||||
Boxed Weight | N/A 5 lb2.3 kg | N/A 5 lb2.3 kg | N/A 6 lb2.7 kg | N/A 8 lb3.5 kg | N/A 8 lb3.5 kg | |||||
Typical Operating Pressure | N/A 140 - 400 psig965 - 2758 kPa | |||||||||
Typical Operating Flux | N/A 10 - 18 GFD17 - 30 LMH | |||||||||
Maximum Pressure | N/A 450 psig3103 kPa | |||||||||
Maximum Operating Temperature | N/A 86 ºF30 ºC | |||||||||
Maximum Cleaning Temperature | N/A 86 ºF30 ºC | |||||||||
Operating Range Recommended pH | N/A 5.0 - 6.5 | |||||||||
Cleaning Range Recommended pH | N/A 3.0 - 8.0 | |||||||||
Recommended Pressure Drop Over an Element | N/A 12 psig83 kPa | |||||||||
Recommended Pressure Drop Per Housing | N/A 50 psig345 kPa | |||||||||
Chlorine Tolerance |
N/A
1 ppm Maximum Continuous 30 ppm for 30 min. During Sanitization |
|||||||||
Feedwater | N/A NTU < 1 SDI < 5 | |||||||||
Note |
N/A
These elements are shipped dry. Trademark of General Electric Company; may be registered in one or more countries. |
|||||||||
|