Polyflow®'s random fiber polypropylene depth media provides long on-stream life and high retention efficiencies. While many polypropylene depth media are nominally rated and cannot meet their actual claimed retention efficiency, Polyflow® is engineered to meet exacting performance claims.
Parker's innovative research team developed an exclusive calendaring process that produces media with unsurpassed dirt-loading capacity. Before each lot of media is fabricated, the best calendaring conditions are determined to ensure minimal lot-to-lot variability and peak product performance. The number of pleats for each filter rating has also been optimized to ensure maximum dirt-loading capacity and on-stream life.
Polyflow® is thermally bonded from 100% virgin polypropylene to ensure superior cleanliness and excellent chemical and thermal compatibility under harsh processing conditions.
Specifications
Filter Rating |
N/A 0.6 µm1.2 µm2.5 µm5.0 µm10.0 µm20.0 µm40.0 µm |
Insert Style |
N/A None (STD) |
End Fittings |
N/A 222/Flat |
Nominal Length |
N/A 20 in500 mm |
Gasket/O-Ring Material |
N/A Buna N EPDM FEP Encapsulated Silicone (O-Rings only) FEP Encapsulated Viton® (O-Rings only) None Silicone Viton® |
Thickness (Gaskets only) |
N/A 0.125" (3 mm) 0.200" (5 mm) (1) 0.200" (5 mm) & (1) 0.125" (3 mm) No Gasket |
Maximum Forward Differential Pressure/Temperature @ 75ºF (24ºC) |
N/A 80 psid5.5 bar |
Maximum Reverse Differential Pressure/Temperature @ 75ºF (24ºC) |
N/A 40 psid2.8 bar |
Maximum Reverse Differential Pressure/Temperature @ 140ºF (60ºC) |
N/A 15 psid1.0 bar |
Effective Filtration Area per 5 inch (130 mm) Cartridge |
N/A 2.4 ft²0.22 m² |
Effective Filtration Area per 10 inch (250 mm) Cartridge |
N/A 4.9 ft²0.46 m² |
Filtration Ratings |
N/A The 0.6 µm offers typical retention up to 99% efficiency. 1.2 µm, 2.5 µm, 5 µm, 10µm, 20 µm, and 40 µm are up to 99.9% efficient at specified pore size |
Filtration Cleanliness |
N/A Cartridge extractables NVR < 35 mg per 10 inch (250 mm) cartridge |
Maximum Operating Temperature |
N/A 160 ºF71 ºC |
Typical Water Flow Rates1 | N/A 0.6 µm - 4.2 gpm/psid (23.3 lpm/100 mbar) 1.2 µm - 5.0 gpm/psid (27.4 lpm/100 mbar) 2.5 µm - 13.5 gpm/psid (74.1 lpm/100 mbar) 5.0 µm - 26.0 gpm/psid (142.7 lpm/100 mbar) 10.0 µm - 40.0 gpm/psid (219.6 lpm/100 mbar) 20.0 µm - 50.0 gpm/psid (274.4 lpm/100 mbar) 40.0 µm - 60.0 gpm/psid (329.3 lpm/100 mbar) |
Materials of Construction
Depth Media Material |
N/A Polypropylene |
Support Layers |
N/A Polypropylene |
Structure |
N/A Polypropylene |
Benefits
N/A
|
Steam Sterilizable and Sanitizable
N/A Cartridges can be steam sterilized for multiple cycles at 266ºF (130ºC) or sanitized for at least ten 30-minute cycles with 176ºF (80ºC) water. They are compatible with most sanitizing agents. |
Technical Support and Product Information
N/A
Parker provides our customers with unsurpassed product consistency and cost efficiency. Our experienced professionals can help you select the right solution for your application. Orders can be emailed directly to PAFsales@parker.com. For additional information contact your local distributor. Information on product specifications, applications and chemical compatibility can be found on our web site at www.parker.com or through the Oxnard office. |
- 1 Per 10-inch (250 mm) cartridge equivalent and for fluids with viscosity of 1cP