The H-Series proprietary thin-film nanofiltration membrane elements are characterized by an approximate molecular weight cut-off of 150-300 daltons for uncharged organic molecules. Divalent and multivalent ion rejection is dependent upon feed concentration and composition.
HL Nanofiltration Elements are used for water softening, color removal, and reduction of THM potential.
HL Nanofiltration Elements are used for water softening, color removal, and reduction of THM potential.
Unit of Measure
Element Specification
Membrane |
N/A H-Series, Thin-Film Membrane (TFM™) |
Flow Average |
N/A 2400 gpd9.1 m³/day |
Salt Rejection Average (MgSO4) |
N/A 98.0 % |
Salt Rejection Minimum (MgSO4) |
N/A 96.0 % |
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 2,000ppm MgSO4 solution at 100psig (690 kPa) operating pressure, 77ºF, pH7.5 and 15% recovery. |
Active Area |
N/A 89 ft²8.2 m² |
Outer Wrap |
N/A Tape |
Part Number |
N/A 1220990 |
Dimensions and Weight
Dimension A (Length) |
N/A 40.0 in101.6 cm |
Dimension B1 | N/A 0.75 inOD: 1.90 cm |
Dimension C (Outside Diameter) |
N/A 3.9 in9.9 cm |
Boxed Weight |
N/A 8 lb3.5 kg |
Operating and CIP parameters
Typical Operating Pressure |
N/A 70 - 300 psig483 - 2069 kPa |
Typical Operating Flux |
N/A 10 - 20 GFD15 - 35 LMH |
Maximum Pressure (Tape Elements) |
N/A 450 psig3103 kPa |
Maximum Pressure (Other Outerwrap) |
N/A 600 psig4140 kPa |
Maximum Operating Temperature |
N/A 122 ºF50 ºC |
Maximum Cleaning Temperature |
N/A 104 ºF40 ºC |
Optimum Rejection Recommended pH |
N/A 6.0 - 7.0 |
Operating Range Recommended pH |
N/A 3.0 - 9.0 |
Cleaning Range Recommended pH |
N/A 2.0 - 10.5 |
Recommended Pressure Drop Over an Element |
N/A 12 psig83 kPa |
Recommended Pressure Drop Per Housing |
N/A 50 psig345 kPa |
Chlorine Tolerance |
N/A 1,000+ ppm-hours, Dechlorination Recommended |
Feedwater |
N/A NTU < 1 SDI < 5 |
- 1 Internal diameter unless specified OD (outside diameter).