AD HR Series Seawater RO High Rejection Elements
RO-NF-UF Membranes
The AD HR series, family of proprietary thin film reverse osmosis membrane elements, is characterized by an excellent sodium chloride rejection. AD HR series is selected when high quality permeate is demanded from seawater that is relatively high in TDS.
AD HR series new membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceeding 800psi (5,516kPa) and elevated temperatures).
AD HR series new membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceeding 800psi (5,516kPa) and elevated temperatures).
Unit of Measure
Items |
/Asset/Element-Dimensions-Diagram---Male.JPG AD4040FM HR AD HR Series Seawater RO High Rejection Elements |
/Asset/Element-Dimensions-Diagram---Male.JPG AD8040F HR AD HR Series Seawater RO High Rejection Elements |
/Asset/Element-Dimensions-Diagram---Male.JPG AD8040F-400 HR AD HR Series Seawater RO High Rejection Elements |
|||
Membrane | N/A Thin-Film Membrane (TFM™) | |||||
Average Permeate Flow | N/A 1400 gpd5.3 m³/day | N/A 6000 gpd22.7 m³/day | N/A 6500 gpd24.6 m³/day | |||
Average NaCl Rejection | N/A 99.7 % | |||||
Minimum NaCl Rejection | N/A 99.3 % | |||||
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 32,000mg/l NaCl solution at 800psi (5,516kPa) operating pressure, 77ºF, pH7.5 and 7% recovery. |
|||||
Active Area | N/A 86 ft²8.0 m² | N/A 370 ft²34.4 m² | N/A 400 ft²37.2 m² | |||
Outer Wrap | N/A Fiberglass | |||||
Part Number | N/A 3034297 | N/A 3037409 | N/A 3037470 | |||
Dimension A (Length) | N/A 40.0 in101.6 cm | |||||
Dimension B1 | N/A 0.75 inOD: 1.90 cm | N/A 1.125 in2.86 cm | N/A 1.125 in2.86 cm | |||
Dimension C (Outside Diameter) | N/A 3.9 in9.9 cm | N/A 7.9 in20.1 cm | N/A 7.9 in20.1 cm | |||
Boxed Weight | N/A 9 lb4 kg | N/A 35 lb16 kg | N/A 35 lb16 kg | |||
Typical Operating Pressure | N/A 800 psi5516 kPa | |||||
Typical Operating Flux | N/A 7 - 11 GFD12 - 19 LMH | |||||
Maximum Operating Pressure | N/A 1200 psi8274 kPa | |||||
Maximum Continuous Operation Temperature | N/A 122 ºF50 ºC | |||||
Maximum Clean-In-Place (CIP) Temperature | N/A 122 ºF50 ºC | |||||
Optimum Rejection pH Range | N/A 7.0 - 7.5 | |||||
Continuous Operation pH Range | N/A 4.0 - 11.0 | |||||
Clean-In-Place (CIP) pH Range | N/A 2.0 - 11.5 | |||||
Maximum Pressure Drop Over an Element | N/A 12 psi83 kPa | |||||
Maximum Pressure Drop Per Housing | N/A 50 psi345 kPa | |||||
Chlorine Tolerance | N/A 1,000+ ppm-hours, Dechlorination Recommended | |||||
Feedwater | N/A NTU < 1 SDI < 5 | |||||
Note |
N/A
These elements are bagged wet before shipping. Trademark of General Electric Company; may be registered in one or more countries. |
|||||
|