CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate)
RO-NF-UF Membranes
The C-Series family, a triacetate/diacetate blend, has a higher flux and better mechanical stability than standard cellulose acetate. C-Series elements offer a lower per element cost and increased chlorine resistance compared to thin-film elements.
CD High Rejection Elements are used for brackish water desalination and process stream concentration at 425 psig operating pressure (2,930 kPa).
CD High Rejection Elements are used for brackish water desalination and process stream concentration at 425 psig operating pressure (2,930 kPa).
Unit of Measure
Items |
/Asset/Element-Dimensions-Diagram---Male.JPG CD4025T CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate) |
/Asset/Element-Dimensions-Diagram---Male.JPG CD4040F CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate) |
/Asset/Element-Dimensions-Diagram---Male.JPG CD8040F CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate) |
|||
Membrane | N/A C-series, Cellulose Acetate | |||||
Flow Average | N/A 1025 gpd3.9 m³/day | N/A 1600 gpd6.1 m³/day | N/A 6000 gpd22.7 m³/day | |||
Salt Rejection Average (NaCl) | N/A 98.5 % | |||||
Salt Rejection Minimum (NaCl) | N/A 96.5 % | |||||
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 2,000ppm NaCl solution at 425psig (2,930 kPa) operating pressure, 77ºF, pH 6.5 and 15% recovery. |
|||||
Active Area | N/A 55 ft²5.1 m² | N/A 90 ft²8.4 m² | N/A 390 ft²36.2 m² | |||
Outer Wrap | N/A Tape | N/A Fiberglass | N/A Fiberglass | |||
Part Number | N/A 1206834 | N/A 1206835 | N/A 1206837 | |||
Dimension A (Length) | N/A 25.0 in63.5 cm | N/A 40.0 in101.6 cm | N/A 40.0 in101.6 cm | |||
Dimension B1 | N/A 0.625 in1.59 cm | N/A 0.625 in1.59 cm | N/A 1.125 in2.86 cm | |||
Dimension C (Outside Diameter) | N/A 3.9 in9.9 cm | N/A 3.9 in9.9 cm | N/A 7.9 in20.1 cm | |||
Boxed Weight | N/A 5 lb2.3 kg | N/A 8 lb3.5 kg | N/A 32 lb14.5 kg | |||
Typical Operating Pressure | N/A 140 - 400 psig965 - 2758 kPa | |||||
Typical Operating Flux | N/A 10 - 18 GFD17 - 30 LMH | |||||
Maximum Pressure | N/A 450 psig3103 kPa | |||||
Maximum Operating Temperature | N/A 86 ºF30 ºC | |||||
Maximum Cleaning Temperature | N/A 86 ºF30 ºC | |||||
Operating Range Recommended pH | N/A 5.0 - 6.5 | |||||
Cleaning Range Recommended pH | N/A 3.0 - 8.0 | |||||
Recommended Pressure Drop Over an Element | N/A 12 psig83 kPa | |||||
Recommended Pressure Drop Per Housing | N/A 50 psig345 kPa | |||||
Chlorine Tolerance |
N/A
1 ppm Maximum Continuous 30 ppm for 30 min. During Sanitization |
|||||
Feedwater | N/A NTU < 1 SDI < 5 | |||||
Note |
N/A
These elements ship dry. Trademark of General Electric Company; may be registered in one or more countries. |
|||||
|