Industry’s Filtration Partner
The C-Series family, a triacetate/diacetate blend, has a higher flux and better mechanical stability than standard cellulose acetate. C-Series elements offer a lower per element cost and increased chlorine resistance compared to thin-film elements.

CD High Rejection Elements are used for brackish water desalination and process stream concentration at 425 psig operating pressure (2,930 kPa).
Unit of Measure
Items
Element-Dimensions-Diagram---Male

CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate)

Element-Dimensions-Diagram---Male

CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate)

Element-Dimensions-Diagram---Male

CD Series High Rejection Brackish Water RO Elements (Cellulose Acetate)
Membrane N/A C-series, Cellulose Acetate
Flow Average N/A 1025 gpd3.9 m³/day N/A 1600 gpd6.1 m³/day N/A 6000 gpd22.7 m³/day
Salt Rejection Average (NaCl) N/A 98.5 %
Salt Rejection Minimum (NaCl) N/A 96.5 %
Note N/A Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%.
Testing conditions: 2,000ppm NaCl solution at 425psig (2,930 kPa) operating pressure, 77ºF, pH 6.5 and 15% recovery.
Active Area N/A 55 ft²5.1 m² N/A 90 ft²8.4 m² N/A 390 ft²36.2 m²
Outer Wrap N/A Tape N/A Fiberglass N/A Fiberglass
Part Number N/A 1206834 N/A 1206835 N/A 1206837
Dimension A (Length) N/A 25.0 in63.5 cm N/A 40.0 in101.6 cm N/A 40.0 in101.6 cm
Dimension B1 N/A 0.625 in1.59 cm N/A 0.625 in1.59 cm N/A 1.125 in2.86 cm
Dimension C (Outside Diameter) N/A 3.9 in9.9 cm N/A 3.9 in9.9 cm N/A 7.9 in20.1 cm
Boxed Weight N/A 5 lb2.3 kg N/A 8 lb3.5 kg N/A 32 lb14.5 kg
Typical Operating Pressure N/A 140 - 400 psig965 - 2758 kPa
Typical Operating Flux N/A 10 - 18 GFD17 - 30 LMH
Maximum Pressure N/A 450 psig3103 kPa
Maximum Operating Temperature N/A 86 ºF30 ºC
Maximum Cleaning Temperature N/A 86 ºF30 ºC
Operating Range Recommended pH N/A 5.0 - 6.5
Cleaning Range Recommended pH N/A 3.0 - 8.0
Recommended Pressure Drop Over an Element N/A 12 psig83 kPa
Recommended Pressure Drop Per Housing N/A 50 psig345 kPa
Chlorine Tolerance N/A 1 ppm Maximum Continuous
30 ppm for 30 min. During Sanitization
Feedwater N/A NTU < 1 SDI < 5
Note N/A These elements ship dry.
Trademark of General Electric Company; may be registered in one or more countries.
  • 1 Internal diameter unless specified OD (outside diameter).