The C-Series family, a triacetate/diacetate blend, has a higher flux and better mechanical stability than standard cellulose acetate. C-Series elements offer a lower per element cost and increased chlorine resistance compared to thin-film elements.
CG High Flux Elements are used for brackish water desalination and process stream concentration at 225 psig (1,551 kPa) operating pressure.
CG High Flux Elements are used for brackish water desalination and process stream concentration at 225 psig (1,551 kPa) operating pressure.
Unit of Measure
Element Specification
Membrane |
N/A C-series, Cellulose Acetate |
Flow Average |
N/A 7300 gpd27.6 m³/day |
Salt Rejection Average (NaCl) |
N/A 93.0 % |
Salt Rejection Minimum (NaCl) |
N/A 85.0 % |
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 500 ppm NaCl solution at 210 psig (1,448 kPa) operating pressure, 77ºF, pH 6.5 and 15% recovery. |
Active Area |
N/A 350 ft²32.5 m² |
Outer Wrap |
N/A Fiberglass |
Part Number |
N/A 1206896 |
Dimensions and Weight
Dimension A (Length) |
N/A 40.0 in101.6 cm |
Dimension B1 | N/A 1.125 in2.86 cm |
Dimension C (Outside Diameter) |
N/A 7.9 in20.1 cm |
Boxed Weight |
N/A 32 lb14.5 kg |
Operating and CIP parameters
Typical Operating Pressure |
N/A 60 - 200 psig414 - 1379 kPa |
Typical Operating Flux |
N/A 10 - 18 GFD17 - 30 LMH |
Maximum Pressure |
N/A 450 psig3103 kPa |
Maximum Operating Temperature |
N/A 86 ºF30 ºC |
Maximum Cleaning Temperature |
N/A 86 ºF30 ºC |
Operating Range Recommended pH |
N/A 5.0 - 6.5 |
Cleaning Range Recommended pH |
N/A 3.0 - 8.0 |
Recommended Pressure Drop Over an Element |
N/A 12 psig83 kPa |
Recommended Pressure Drop Per Housing |
N/A 50 psig345 kPa |
Chlorine Tolerance |
N/A
1 ppm Maximum Continuous 30 ppm for 30 min. During Sanitization |
Feedwater |
N/A NTU < 1 SDI < 5 |
- 1 Internal diameter unless specified OD (outside diameter).