Items |
CG2540FM CG Series High Flux Brackish Water RO Elements (Cellulose Acetate) |
CG4040F CG Series High Flux Brackish Water RO Elements (Cellulose Acetate) |
CG8040F CG Series High Flux Brackish Water RO Elements (Cellulose Acetate) |
|||
Membrane | N/A C-series, Cellulose Acetate | |||||
Flow Average | N/A 600 gpd2.3 m³/day | N/A 2000 gpd7.6 m³/day | N/A 7300 gpd27.6 m³/day | |||
Salt Rejection Average (NaCl) | N/A 93.0 % | |||||
Salt Rejection Minimum (NaCl) | N/A 85.0 % | |||||
Note |
N/A
Average salt rejection after 24 hours operation. Individual flow rate may vary +25%/-15%. Testing conditions: 500 ppm NaCl solution at 210 psig (1,448 kPa) operating pressure, 77ºF, pH 6.5 and 15% recovery. |
|||||
Active Area | N/A 27 ft²2.5 m² | N/A 90 ft²8.4 m² | N/A 350 ft²32.5 m² | |||
Outer Wrap | N/A Fiberglass | |||||
Part Number | N/A 1206891 | N/A 1206893 | N/A 1206896 | |||
Dimension A (Length) | N/A 40.0 in101.6 cm | |||||
Dimension B1 | N/A 0.75 inOD: 1.90 cm | N/A 0.625 in1.59 cm | N/A 1.125 in2.86 cm | |||
Dimension C (Outside Diameter) | N/A 2.4 in6.1 cm | N/A 3.9 in9.9 cm | N/A 7.9 in20.1 cm | |||
Boxed Weight | N/A 5 lb2.3 kg | N/A 8 lb3.5 kg | N/A 32 lb14.5 kg | |||
Typical Operating Pressure | N/A 60 - 200 psig414 - 1379 kPa | |||||
Typical Operating Flux | N/A 10 - 18 GFD17 - 30 LMH | |||||
Maximum Pressure | N/A 450 psig3103 kPa | |||||
Maximum Operating Temperature | N/A 86 ºF30 ºC | |||||
Maximum Cleaning Temperature | N/A 86 ºF30 ºC | |||||
Operating Range Recommended pH | N/A 5.0 - 6.5 | |||||
Cleaning Range Recommended pH | N/A 3.0 - 8.0 | |||||
Recommended Pressure Drop Over an Element | N/A 12 psig83 kPa | |||||
Recommended Pressure Drop Per Housing | N/A 50 psig345 kPa | |||||
Chlorine Tolerance |
N/A
1 ppm Maximum Continuous 30 ppm for 30 min. During Sanitization |
|||||
Feedwater | N/A NTU < 1 SDI < 5 | |||||
Note |
N/A
These elements are shipped dry. Trademark of General Electric Company; may be registered in one or more countries. |
|||||
|