Industry’s Filtration Partner
The Flotrex PN (FPN) microfiber filters (Figure 1) offer an economical solution for your filtration needs. The all polypropylene construction of the FPN filters provides superior chemical compatibility. The gradient density, thermally bonded polypropylene media has excellent dirt holding capacities and reliable retention characteristics. FPN filters do not contain any adhesives or additives.
Unit of Measure

Specifications

Type

N/A FPN

Nominal Micron Rating

N/A 0.2 µm

Nominal Cartridge Length

N/A 20 in51 cm
End #1 Adapter1 N/A 020 O-Ring

End #2 Adapter

N/A 120 O-Ring 213 O-Ring Closed End Cap Fin Adapter Open End Gasket
Elastomer Material2 N/A Buna-N EPDM PTFE Silicone Viton

Note

N/A Trademark of General Electric Company; may be registered in one or more countries

Materials of Construction

Filtration Media

N/A Polypropylene Microfiber

Support Layers

N/A Polypropylene Microfiber

Core and Cage

N/A Polypropylene

Endcaps and Adapters

N/A Polypropylene

Dimensions

Filter Model

N/A FPN92

Nominal Outside Diameter

N/A 2.75 in70 mm

Nominal Inside Diameter

N/A 1.25 in31 mm

Effective Filtration Area

N/A 5 ft²0 m²

Operational Limits

Maximum Forward Differential Pressure @ 70ºF (21ºC)

N/A 60 psi4.1 bar

Maximum Reverse Differential Pressure @ 70ºF (21ºC)

N/A 30 psi2.1 bar

Maximum Operating Temperature at 10 psid (0.69 bar) in Water

N/A 180 ºF82 ºC

Typical Applications

N/A FPN filters are an economical alternative to membrane filters in a broad range of applications, Including:

  • Filtration of liquid polymers, coatings, and inks
  • Filtration of bulk chemicals
  • Beer trap filtration
  • Post Carbon bed and DI bed filtration
  • Pre-filtration to protect expensive final filters

  • General Properties

    N/A Flotrex PN filters are available in the following nominal pore size micron rating: 0.2, 0.45, 1, 2, 3, 5, 10 and 30 µm. Tables 1, 2, 3 and 4 show further details on materials of construction, dimensions, operational limits and flow performance.

    Additional Information

    N/A

    • Flotrex PN filters may be autoclaved or in situ steam sterilized (up to 257ºF [125ºC], 30-minute cycles) for a maximum accumulated exposure of 10 hours. Alternately, the filters may be sanitized with compatible chemical agents.
    • GE certifies that the material contained in its Flotrex PN pleated filters meet U.S. FDA requirements for food contact under the applicable regulations in 21 CFR. For further information, contact GE technical services. Flotrex PN filters meet the test criteria for USP class VI- 121ºC Plastics.
    • Aqueous extracts from Flotrex PN filters contain less that 0.25 EU/ml. The filters typically exhibit low levels of non-volatile residues.
    • GE filter cartridges are designed and manufactured for resistance to a wide range of chemical solutions. Conditions will vary with each application and users should carefully verify chemical compatibility. Please contact your GE distributor for more information.

    • 1 222 O-Ring Stainless Steel Insert or 226 O-Ring Stainless Steel Insert Adapters normally require Closed End Cap or Fin Adapters.
    • 2 PTFE and Viton on are registered trademarks of DuPont