Every process is unique - that’s why we offer several backwashing/tubular systems in several configurations.
Our flagship tubular systems. During backwash, a single tube is taken off-line from the process flow via a three-way valve. Once an element is clean, it is returned to service and the next element may be cleaned. The remaining elements in the filter remain operational throughout this cycle. F-Series and AFC-Series multiplex units consist of 2-20 individual tubes valved in parallel to common inlet, outlet, and drain headers. AFC-Series units are also available in economical single and duo-tube configurations, which must be removed from service for manual cleaning.
AFC-Series - high-pressure capability and modular flexibility
When your application demands high-pressure operation - up to 1,000 psi (69 bar) - and scaleable flexibility, the Ronningen-Petter AFC-Series is optimal. AFC-Series systems are available in single-, duo-, and multiplex configurations to meet your application and business demands.
Duo Filters
Ronningen-Petter AFC-Series duo filters consist of two single filter units connected to a pair of 3-way valves for continuous service during cleaning or maintenance. For this reason, duo filters are typically rated at the same capacity as a single. But, for intermittent service applications, the valves can be positioned so that both units operate simultaneously.
350 (24.1 bar), 740 (51.7 bar), and 1000 (101.3 bar) psi available in strate-thru design only. All high pressure units incorporate 2-way ball valves.
Specifications
Strainer Model |
N/A AFC 2200 Duo Unit |
Body Inlet / Outlet Size |
N/A 2 in50.8 mm |
Screen Length |
N/A 18 in36 in457.2 mm914.4 mm |
Element Styles Available1 | N/A 3.25 in (82.8mm) Diameter Single, Tri-Cluster, Accuflux - 7 |
Body Diameter |
N/A 4.5 in114.3 mm |
Standard Pressure Rating2 | N/A 150 psi10.3 bar |
High Pressure Rating3 | N/A 250 psi350 psi740 psi1000 psi17.2 bar24.1 bar51.7 bar101.3 bar |
Total Volumetric Capacity - model # |
N/A 2218 2236 |
Total Volumetric Capacity |
N/A 2.6 gal4.8 gal9.8 L18.2 L |
Standard Drain Size |
N/A 1.25 in31.75 mm |
Strate-Thru Drain Size |
N/A 0.5 in12.7 mm |
Total Unit Weight |
N/A 140 lb160 lb63.5 kg72.6 kg |
Filter Media Material4 | N/A Fabric: 230 - 1 micron Slotted: 1,600 - 25 microns Wire mesh: 1,650 - 2 microns |
Note |
N/A
4350 (24.1 bar), 740 (51.7 bar), and 1000 (101.3 bar) psi available in strate-thru design only. All high pressure units incorporate 2-way ball valves. Consult factory for optional additional drain sizes. |
Cake Formation Increases Operational Efficiency
N/A
While the filtration media provides some of the filtration action, collected contaminants actually further increase efficiency. We call this phenomenon "cake formation." The collected solids (or "cake") trap additional contaminants. The key to making this principle work is timely cleaning - too soon and you lose the benefit, too late and the system flow becomes hindered. |
- 1 Consult media availability chart for specific retentions and types available.
- 2 PTFE gaskets limit pressure maximum to 80 psi (5.5 bar).
- 3 PTFE gaskets limit pressure maximum to 80 psi (5.5 bar).
- 4 See downloads for more details.